Frequently Asked Questions

Looking for help? Here are our
most frequently asked questions.

  • Everything you need to know about ICP DAS USA and our products. Can’t find the answer
  • to a question you have? No worries, just click ‘Submit a question’ or ‘Chat with our Team’!
  • In most cases, yes. An AVEVA Edge runtime license can run projects created with older development versions, as long as the runtime license version is…

    Read More →

    Before you do anything make a backup copy of your project. Convert resolution does not always reverse well. Having a backup allows you to recover…

    Read More →

    A: The first thing that you need to check is what is the aspect ratio of each display. The aspect ratio is the width /…

    Read More →

    The maximum data throughput for all CAN channels combined on the I-2534 and I-5534-M modules is up to 2,500 frames per second (FPS). This total…

    Read More →

    The Automatic Baseline Correction (ABC) function on the ICP DAS CL-200 Series CO₂ sensor compensates for long-term sensor drift by recalibrating the baseline CO₂ level…

    Read More →

    Hardware

    A: Please refer to the “PciCardNo.jpg” picture. In normal PC, the PCI card in the slot closest to the CPU will be the first one,…

    Read More

    A: Please refer to pioda16.pdf Document:

    Read More

    A: No, you cannot make a loop-back test on one RS-485 port. In RS-232, the TX signal is used for output while the RX signal…

    Read More

    A: It is about 0.77 us (1.3 MHz max.), please refer to the test report PIO_Response_Time.pdf.

    Read More

    A: ADC conversion rate is the specification of ADC chip that defines its maximum conversion speed, while the sampling rate is limited by the ADC,…

    Read More

    A: Yes, please refer to the VXC_Customized_Baudrate_English.pdf document:

    Read More

    A: The golden fingers can be oxidized and dusts residue after months or years that may cause the host PC cannot find the PCI/ISA/PEX cards.…

    Read More

    A: Please refer to floating for digital inputs_eng.pdf document.

    Read More

    Software

    A: The System Administrator has to protect the PC from virus, security … and unstability. Thus, it’s not proper (and should not) to install any…

    Read More

    A: No. The drivers use x86 direct I/O commands to get the highest performance. It doesn’t access through the HAL interface, so it works with…

    Read More

    A: The PIO_PISO.EXE directly gets information of devices from PCI bus controller, so it should be always no problem to list PCI cards. But it’s…

    Read More

    A: You can record the Base-Address of all cards first, and then calling I/O functions directly without ActiveBoard()function calls anymore. For example, to use ISO-P64…

    Read More

    A: Please refer to vc++.net_with_activex.pdf document:

    Read More

    A. Please refer to Using_The_ICPDAS_IO_Card_DLL_In_VBdotNET.pdf document:

    Read More

    A: Please refer to the Using_DLL_in_CShape.NET_2005_eng.pdf document:

    Read More

    A: Please refer to the please refer to the Using_DLL_in_VB.NET_2005_eng.pdf document:

    Read More

    A: Please refer to Using_DAQCard_in_XP_Embedded_Eng.pdf document:

    Read More

    A: Please refer to PCI-P16R16_PISO-P16R16U_compatible_Eng.pdf document:

    Read More

    A: Please refer to Matlab_for_IOCARD_eng.pdf Document:

    Read More

    A: Please refer to How_to_use_CardID_eng.pdf document:

    Read More

    A: Please refer to FAQ17_en.pdf document:

    Read More

    A: Please refer to TMC12A Initialization_eng.pdf document:

    Read More

    If the IP address of an EIP-2000 Series module is unknown, the device can be restored to its factory default network settings using firmware mode…

    Read More →

    If the analog input (AI) status displayed by the EIP-2000 Series module does not match the real-world signal, verify the hardware configuration and firmware version…

    Read More →

    A: The “Arial Unicode MS” font in Microsoft Word 2003 is necessary for using universal language in the EKAN display.        If you…

    Read More →

    When using universal language or multi-language in EKAN, the “DLite Message Editor” may not display well as below. For example, an universal language in Microsoft…

    Read More →

    1. Please refer to faq082.pdf Document

    Read More →

    Please refer to the How to use FRnet Document:

    Read More →

    A: The pins of 7188xc are open collectors. See the picture below for more details.

    Read More →

    The manufacturer’s user manual documents a reset procedure using the module’s physical Init/Run switch. This is a recovery procedure, not a routine troubleshooting step. Before…

    Read More →

    Intermittent communication loss can originate from the power supply, Ethernet network, serial wiring, communication timeouts, or watchdog settings. The tGW-715i supports IEEE 802.3af Class 1…

    Read More →

    Yes. The tGW-715i supports up to 32 TCP connections (masters) per serial port, according to the manufacturer’s tGW-715i specification. This allows multiple systems, such as…

    Read More →

    The Read Cache function stores previously retrieved data so the gateway can respond to repeated requests more quickly without unnecessarily querying the serial device every…

    Read More →

    The gateway provides several timing parameters on its Port1 configuration page. These control how long the module waits for a response, identifies serial message boundaries,…

    Read More →

    These codes help identify why a gateway request did not complete successfully.   Error Code Meaning Recommended action 0x0B The target slave did not respond…

    Read More →

    A successful Ethernet connection confirms only that some network communication is working. It does not prove that the serial slave is wired correctly or responding…

    Read More →

    The tGW-715i has a built-in web server that lets you configure its IP address, serial port parameters, pair-connection settings, and other options. If you cannot…

    Read More →

    The Application Mode setting in the Pair-Connection Settings section determines how the serial port communicates with a remote network Modbus device. Application mode Function Typical…

    Read More →

    A pair-connection can carry serial Modbus communications over an Ethernet or routed TCP/IP connection. This is useful when two serial devices must exchange Modbus messages…

    Read More →

    This is a reverse-direction application compared with the conventional Modbus TCP-master-to-serial-slave arrangement. ICP DAS documents this configuration in its official tGW-700 Series FAQ. For example,…

    Read More →

    RS-422 generally uses separate transmit and receive differential pairs, unlike a typical two-wire half-duplex RS-485 connection. Use the applicable tGW-715i wiring diagram to connect the…

    Read More →

    The tGW-715i supports an isolated RS-485 interface with automatic transmit-direction control. For a typical two-wire RS-485 network, use a twisted-pair cable and connect the differential…

    Read More →

    The serial settings on Port1 must match the serial device or devices connected to the gateway. A mismatch can prevent communication even when the Ethernet…

    Read More →

    DHCP allows the gateway to obtain its IPv4 network settings automatically from a DHCP server. This is useful when your network administrator manages addresses centrally.…

    Read More →

    A static IP address is often preferred for industrial equipment because PLCs, HMIs, and SCADA systems need a predictable address for communication. 1. Connect to…

    Read More →

    The configuration is similar to the RTU application, but the gateway’s serial protocol must be set to Modbus ASCII. 1. Discover the tGW-715i with eSearch…

    Read More →

    This is the standard application when an Ethernet-based PLC, HMI, or SCADA master needs to communicate with one or more serial Modbus RTU slave devices.…

    Read More →

    The tGW-715i supports Modbus TCP/UDP master and slave roles and Modbus RTU/ASCII master and slave roles. Its supported application depends on how the serial port…

    Read More →

    The tGW-715i connects Ethernet-based Modbus applications to serial Modbus devices that communicate using RS-485 or RS-422. It translates messages between Modbus TCP/UDP and Modbus RTU/ASCII…

    Read More →

    It is configured using a built in web server.

    Read More →

    The read-cache is a memory buffer storing data from previous requests, which can reduce serial traffic and improve response times. When multiple master devices need…

    Read More →

    The TGW-715 supports up to 32 concurrent TCP connections.

    Read More →

    The TSH-725 acts as a repeater and communication converter. It changes the baud rate, parity and stop bits for each RS-485 bus. It also has…

    Read More →

    Yes, the TSH-735 supports raw data mode for protocols like DCON and other query – response protocols.

    Read More →

    The TSH-735 allows multiple Modbus or serial master devices to communicate to a set of shared slave devices. The most common use is multiple Modbus…

    Read More →

    The ICP DAS TGW-715 is a Modbus TCP to Modbus RTU gateway designed to integrate legacy RS-485 PLCs and field devices into modern Ethernet-based SCADA…

    Read More →

    The MDC-711 supports up to 250 total polling definitions, with each definition allowing up to 125 registers when using firmware version 1.08 or later. Modbus…

    Read More →

    The heartbeat LED flashing at approximately 1 Hz indicates normal system operation. The Ethernet 10/100M LED illuminates orange for 100 Mbps connections and remains off…

    Read More →

    Firmware updates for the ICP DAS USA MDC-711 are performed using the MiniOS7 Utility, which is available from ICP DAS USA website. Connect the device…

    Read More →

    In firmware version 1.08 and later, you can configure timeout behavior per polling definition: 0 – Return exception code: reports a Modbus communication error when…

    Read More →

    To restore the ICP DAS MDC-711 to factory default settings, short the RESET and GND pins for more than 3 seconds while the unit is…

    Read More →

    Please refer to Input register photo:

    Read More →

    The DL-10 measures Temperature, relative humidity and dew point (calculated based on temperature and humidity).

    Read More →

    Yes. The ICP DAS DL-10 is a Modbus RTU temperature and humidity sensor designed for building automation, data centers, and factory environments. It operates as…

    Read More →

    The PM-3133 Series power meters analyze harmonic components within a 2.8 kHz measurement bandwidth. The maximum number of harmonics that can be calculated depends on…

    Read More →

    If the PM-3133 Series power meter cannot communicate over RS-485, verify the following configuration and wiring parameters. Modbus address.Confirm the device address matches the master…

    Read More →

    In a three-phase wye connected electrical system, voltage can be measured in two primary ways. Line-to-line voltage is the voltage measured between any two phase…

    Read More →

    Negative kW readings on the ICP DAS PM-3114 power meter are typically caused by incorrect current transformer (CT) orientation or wiring sequence during installation. Each…

    Read More →

    Yes. The ICP DAS USA I-7561, I-7561U, and TM-7561 USB to RS-485 converters all provide a built-in 5 Volt bias voltage across the RS-485 port,…

    Read More →

    Wireless signal performance depends on site conditions such as building materials, distance, electromagnetic interference, and physical obstructions. For optimal performance of the ICP DAS ZT-2000…

    Read More →