| Share On: | |
|---|---|
| Categories: | tSH-700 Serial Port Sharing Devices |
| Review: | Write your review |
| Resources: |
The tSH-734i module is a tiny serial port sharer with 1 RS-485 port and 2 RS-232 ports that provides functions such as "Baud Rate Conversion", "Modbus RTU/ASCII Conversion" and "Two Masters Share One Slave". It has a built-in web server that provides web management interface for easy configuration on a web page.
The Baud Rate Conversion function allows different baud rates and data formats to be sent among master and slave devices. Modbus RTU/ASCII Conversion allows for a single Modbus RTU master device to communicate with Modbus RTU/ASCII slave devices through different protocols, baud rates, and formats. It is very compact, and equipped with removable terminal block connectors for easy wiring. The tSH-734i can also be powered over Ethernet, which complies with true IEEE 802.3af-compliant (Class 1) standard. tSH-700 module is designed for low power consumption - it helps save energy.

Allow a Master device to communicate with Slave devices with different Baud Rate or Data Format. In the Raw Data mode, it can be applied to most of the half-duplex communications that do not require protocol conversion (Request - Response), such as DCON. When the Data Size is less than 512 bytes buffer size (built-in buffer for each serial port), it can perform full-duplex communication.

Allow a Modbus RTU/ASCII Master device to communicate with a Modbus RTU/ASCII Slave device with different Protocol, Baud Rate or Data Format.

Allows two Master devices to connect to different serial ports and access to the Slave device. Modbus mode can be used to convert Modbus RTU/ASCII protocol, and Raw Data Mode can be used for DCON or other Request - Response protocols. Each serial port can be configured with different Baud Rate or Data Format that depends on connected devices. When two Master devices request the same Modbus information, the built-in Cache function will remove duplicated request message to reduce the load of communication of the Slave device serial port. Note: It may need to set up a longer Timeout for the Upper Computer.
Modbus Protocol and Baud Rate Conversion Function

Baud Rate Conversion in Raw Data Mode

Connect the two uplink serial ports on the tSH-735 module to the two control panels (Master controller such as TPD/HMI) in the front area as well as the back area of the office. And connect the downlink serial port on the tSH-735 module to the lighting control circuit (RS-485 bus). And then the lighting control of the office can be done by using the Master controller (TPD/HMI) in different locations.

In this production line application, the monitoring & control center (HMI/SCADA) is connected to uplink serial ports on the tSH-734i module of the production line 1 and production line 2 via RS-485. And then the on-site Master controller (Panel PC) of the production line 1 and production line 2 are connected to another uplink serial port on the tSH-734i module via RS-232. Furthermore, the downlink serial port on the tSH-734i module is connected to the slave process controller (PAC/PLC) and then each on-site I/O module can be connected to the RS-485 serial port on the slave process controller (PAC/PLC) to achieve monitoring and control of the production process from the Monitoring & control center or from the on-site controllers.

| System | ||
| CPU | 32-bit ARM | |
| Communication Interface | ||
| Ethernet | 10/100 Base-TX, 8-pin RJ-45 x 1 (Auto-negotiating, Auto-MDI/MDIX, LED indicator) PoE (IEEE 802.3af, Class 1) |
|
| COM1 | 2-wire RS-485 | |
| COM2 | 3-wire RS-232 | |
| COM3 | 3-wire RS-232 | |
| Self-Tuner | Yes, automatic RS-485 direction control | |
| RS-485 | Bias Resistor | Yes, 1 KΩ |
| Node | 254 (max.) | |
| UART | 16c550 or compatible | |
| COM Port Format | ||
| Baud Rate | 115200 bps Max. | |
| Data Bit | 5, 6, 7, 8 | |
| Parity | None, Odd, Even, Mark, Space | |
| Stop Bit | 1, 2 | |
| Power | ||
| Power Input | PoE | IEEE 802.3af, Class 1 |
| DC Jack | +12 ~ 48 VDC | |
| Power Consumption | 0.07 A @ 24 VDC | |
| Mechanism | ||
| Connector | 10-Pin Removable Terminal Block x 1 | |
| Mounting | DIN-Rail | |
| Environment | ||
| Operating Temperature | -25°C ~ +75°C (-13°F ~ +167°F) | |
| Storage Temperature | -30°F ~ +80°C (-22°F ~ +176°F) | |
| Humidity | 10 ~ 90% RH, non-condensing | |