The NSM-206FC is a 4-port unmanaged Ethernet with dual fiber port switch. Using fiber optics, you can prevent noise from interfering with your system and supports high-speed (100 Mbps) and high-distance (up to 2 km) ransmissions. The NSM-206FC provides a wide 10 to 30 VDC power range to fit all the common power standards found in industrial automation, without external power converters. The wide power input lowers installation and maintenance costs.
| EMS Protection | |
|---|---|
| ESD (IEC 61000-4-2) | ± 4 kV Contact |
| LED Indicators | |
|---|---|
| Status | PWR1, PWR2, PWR_Fault, PWR_OK, Link/Act, 10/100M |
| Ethernet | |
|---|---|
| Ports | 4 x RJ-45, 10/100Base-TX |
| Standards | IEEE 802.3, 802.3u, 802.3x |
| Processing Type | Store & forward; wire speed switching |
| MAC Table | 1024 |
| Memory Bandwidth | 1.6 Gbps |
| Frame Buffer Memory | 256 Kbit |
| Flow Control | IEEE 802.3x flow control, back pressure flow control |
| Isolation | 1500 Vrms 1 minute |
| Fiber | |
|---|---|
| Ports | 2 x 100 Base-FX, SC connector |
| Mode | Multi-Mode |
| Fiber Cable | 50/125, 62.5/125 or 100/140 gm |
| Distance | 2 km, (62.5/125 gm recommended) for full duplex |
| Wavelength | 1300 or 1310nm |
| TX Output | -20 dBm Min. -14 dBm Max. |
| RX Sensitivity | -34 dBm |
| Power | |
|---|---|
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +30 VDC (Redundant input) |
| Redundant Power Inputs | Yes |
| Consumption | 0.2 A @ 24 VDC |
| Alarm Output | Yes, Relay 1 A @ 30 VDC |
| Mechanical | |
|---|---|
| Casing | Metal |
| Dimensions (mm) | 73 x 132 x 105 (W x L x H) |
| Installation | DIN-rail mounting or wall mounting |
| Ingress Protection Rating | IP20 |
| Environment | |
|---|---|
| Operating Temperature | 0 °C ~ +70 °C |
| Storage Temperature | -20 °C ~ +85 °C |
| Humidity | 10% ~ 90% RH, non-condensing |