| Share On: | |
|---|---|
| Categories: | ISaGRAF PACs |
| Review: | Write your review |
| Resources: | The product additional data is empty. |
The ISaGRAF iPAC-8000 Series (iP-8417/8817/8447/8847) is the ISaGRAF SoftLogic PAC from ICP DAS. Each WP-8xx7 is equipped with an 80186, 80 MHz CPU running a MiniOS7 operating system, a variety of input/output ports (Dual 10/100 Base-TX Ethernet Ports for iP-8x47, one RS-232/485 port, one RS-485 port and two RS-232 ports) and a range of I/O slots (4/8) that can be used to integrate high performance parallel I/O modules (high profile I-8K Series) or serial I/O modules (high profile I-87K series). Users can also choose RS-485 Remote I/O modules (I-7000 series) or expansion units (RU-87Pn or I-87Kn) plugged with high profile I-87K serial I/O modules. Compared to I-8xx7, iPAC-8xx7 series is 2 ~ 4 times faster!
Measure Humidity and Temperature Values via DL-100TM485
ISaGRAF PAC connects the Smart Meter
ZigBee Wireless Solution
Note: Some of the applications don't support iP-8x17, please click the item for more details.
Click here for "Applications Supporting List" & all applications| Models | iP-8847 | ||||
| System Software | |||||
| OS | MiniOS7 (DOS-like embedded operating system) | ||||
| Development Software | |||||
| ISaGRAF Software | ISaGRAF Ver. 3 | IEC 61131-3 standard | |||
| Languages | LD, ST, FBD, SFC, IL & FC | ||||
| Max. Code Size | 64 KB | ||||
| Scan Time | 2 ~ 25 ms for normal program | ||||
| 10 ~ 125 ms (or more) for complex or large program | |||||
| CPU Module | |||||
| CPU | 80186, 80 MHz | ||||
| SRAM | 768 KB | ||||
| Flash | 512 KB; with Write Protect Switch | ||||
| microSD Expansion | Yes (but ISaGRAF doesn't support) | ||||
| OS | MiniOS7 (DOS-like embedded operating system) | ||||
| Dual Battery Backup SRAM | 512 KB; data valid up to 5 years (for retain variables) | ||||
| EEPROM | 16 KB | ||||
| NVRAM | 31 bytes (battery backup, data valid up to 5 years) | ||||
| RTC (Real Time Clock) | Provide second, minute, hour, date, day of week, month, year | ||||
| 64-bit Hardware Serial Number | Yes, for Software Copy Protection | ||||
| EEPROM | 16 KB | ||||
| Watchdog Timers | Yes (0.8 second) | ||||
| DIP Switch | Yes (8 bits) | ||||
| Communication Ports | |||||
| Ethernet | RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) | ||||
| COM 0 | Internal communication with the high profile I-87K series modules in slots | ||||
| COM 1 | RS-232 (to update firmware) (RxD, TxD and GND); non-isolated | ||||
| COM 2 | RS-485 (Data+, Data-) with internal self-tuner ASIC; 3000 VDC isolated | ||||
| COM 3 | RS-232/RS-485 (RxD, TxD, CTS, RTS and GND for RS-232, Data+ and Data- for RS-485); non-isolated | ||||
| COM 4 | RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated | ||||
| SMMI | |||||
| LED Display | Yes, 5-Digit | ||||
| Programmable LED Indicators | 3 | ||||
| Push Buttons | 4 | ||||
| Buzzer | yes | ||||
| I/O Expansion Slots | |||||
| Slot Number | 8 | ||||
| Note: For High Profile I-8K and I-87K Modules Only | |||||
| Data Bus | 8/16 bits | ||||
| Address Bus Range | 2 K for each slot | ||||
| Mechanical | |||||
| Dimensions (W x L x H) | 231 mm x 132 mm x 111 mm: iP-8417, iP-8447 | ||||
| 355 mm x 132 mm x 111 mm: iP-8817, iP-8847 | |||||
| Installation | DIN-Rail or Wall Mounting | ||||
| Environmental | |||||
| Operating Temperature | -25 ~ +75°C | ||||
| Storage Temperature | -30 ~ +80°C | ||||
| Ambient Relative Humidity | 10 ~ 90% RH (non-condensing) | ||||
| Power | |||||
| Input Range | +10 ~ +30 VDC (non-condensing) | ||||
| Isolation | 1 kV | ||||
| Redundant Power Inputs | Yes, with one power relay (1 A @ 24 VDC) for alarm | ||||
| Capacity | 30 W | ||||
| Consumption | 7.2 W | ||||
| Protocols (Note that certain protocols require optional devices) | |||||
| NET ID | 8 bits DIP switch to assign NET ID as 1 ~ 255 | ||||
| Modbus RTU/ASCII Master | A max. of 2 ports: COM1~5. (To connect to other Modbus Slave devices.) A max. of Modbus_xxx Function Block amount for 2 ports: 128. (*) |
||||
| Modbus RTU Slave | A max. of 2 ports: COM1 and one of COM2 ~ 3. (For connecting ISaGRAF, PC/HMI/OPC Server and HMI panels.) |
||||
| Modbus TCP/IP Slave | (For iP-8x47 only) Two Ethernet ports support Modbus TCP/IP Slave Protocol for connecting ISaGRAF & PC/HMI up to 6 connections. | ||||
| User-defined Protocol | Custom protocols can be applied at COM1~20 using Serial communication function blocks. (*) | ||||
| Remote I/O | One of COM2 ~ 4 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards, or RU-87Pn + I-87K High Profile I/O boards as remote I/O. A max. of 64 I-7000/87K remote I/O modules can connect to one PAC. | ||||
| Fbus | Built-in COM3 Port to exchange data between ICP DAS’s ISaGRAF PACs. | ||||
| Ebus | (LAN2: upper port of iP-8x47 ONLY) Used to exchange data between ICP DAS ISaGRAF Ethernet PACs via the Ethernet port. |
||||
| Send Email | (For iP-8x47 only) Provide functions to send email to a max. of 10 receivers with a single attached file via the Ethernet port through internet. The max. of file size is about 488 KB. |
||||
| SMS: Short Message Service | One of COM4 ~ 5 can link to a GSM Modem to support SMS. The user can request data/control the controller via a cellular phone. The controller can also send data and alarms to the user’s cellular phone. (*) Optional GSM Modem: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem). |
||||
| Modem Link | COM4 can connect a general Modem. Supports PC to remotely download & monitor the controller. | ||||
| MMICON/LCD | One of COM3 or COM4 supports ICP DAS’s MMICON. The MMICON is featured with a 240 x 64 dot LCD and a 4 x 4 Keyboard. User can use it to display picture, string, integer, float, and input a character, string, integer and float. | ||||
| Redundant Bus7000 | Two ISaGRAF PACs can link to remote I-7000 & I-87K High profile I/O modules at the same time. Only one controller is active to control these Remote I/Os. If one is dead, the other one will take over the control of Remote I/Os. | ||||
| CAN/CANopen | COM1 or COM3 ~ 12 can connect to one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One iP-8xx7 supports a max. of 3 RS-232 ports to connect a max. of 3 I-7530. (*) (FAQ-086) | ||||
| FRnet I/O | Enable a max. of 4 pcs. I-8172W boards to be used to connect to FRnet I/O modules, such as FR-2053, FR-2057, FR-32R, FR-32P. (Max. 1024-ch. DI + 1024-ch. DO) (FAQ-082, 154) | ||||
| FTP Client | Enable the FTP Client to upload files from the PAC to a remote FTP server on a PC. (FAQ-151) | ||||
| Optional I/O Functions (Refer to the ISaGRAF PAC I/O Selection Guide for I/O Module list) | |||||
| PWM Output | High Speed PWM Module | I-8088W, 8-ch PWM outputs, software support 1 Hz ~ 100 kHz (non-continuous), duty: 0.1 ~ 99.9 | |||
| DO Module as PWM | 8-ch max. for one controller. 500 Hz max. For Off=1 & On=1 ms Output Square Curve: Off: 1 ~ 32767 ms, On: 1 ~ 32767 ms. Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave) |
||||
| Counters, Encoder, Frequency | Parallel DI Counter | 8-ch. max. for 1 controller. Counter Val: 32-bit.; 500 Hz max. Min. ON & OFF width must > 1 ms Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W. | |||
| Serial DI Counter | Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit) Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W. | ||||
| Remote DI Counter | All remote I-7000/I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535 | ||||
| High Speed Counter | I-87082W: 100 kHz max. 32-bit; I-8084W: 250 kHz max. 32-bit |
||||
| Encoder | I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4M Hz for pulse/direction and cw/ccw input mode. (FAQ-112) I-8084W: 250 kHz max. , 4-ch encoder, can be Dir/Pulse, or Up/Down or A/B phase (Quad. mode); Not support Encoder Z-index. (FAQ-100). |
||||
| Frequency | I-87082W: 2-ch, 1 Hz ~ 100 kHz; I-87088W: 8-ch, 1 Hz ~ 100 kHz; I-8084W: 8-ch, 1 Hz ~ 250 kHz; |
||||
| Motion | Motion Control | Can integrate with one I-8091W (2-axis) or two I-8091W (4-axis) to do motion control. Ethernet communication is also available when doing motion control. | |||
| * Note: The COM5 ~ COM20 ports are located in the expansion boards if they are installed in slots 0 ~ 7 of iP-8xx7. * ISaGRAF FAQ: www.icpdas.com > Support > FAQ > ISaGRAF Soft-Logic PAC * ICP DAS recommends using NS-205/NS-208 or RS-405/408 (Ring Switch) Industrial Ethernet Switches. |
|||||
Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.
Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.
Add a review
Your email address will not be published. Required fields are marked *