The device supports the M-Bus standard (EN-13757, CJ/T-188) and Modbus TCP/RTU function codes 0x03 and 0x04 for reading meter data. It features a default M-Bus port data format of 8 data bits, even parity, and 1 stop bit. The device can support up to 100 M-Bus slaves and includes M-Bus overcurrent protection as well as short-circuit protection. Firmware updates can be performed via the serial p...
Availability: IN STOCK | FASTEST DELIVERY : Saturday, Sep 26 | Enter ZIP below for shipping options
Get Shipping Options
-
+
Buy with one Click
Share On:
Categories: M-bus Gateway
Review: Write your review
Resources:

Introduction

M-Bus (Meter-Bus) is a widely used communication interface for various types of meters, including electricity, water, and heat meters. Its key advantages are ease of installation—thanks to a two-wire system that handles both power and communication—and high reliability. Since M-Bus uses its own physical layer and protocol, it is often integrated with other systems like Modbus to enhance compatibility in broader applications.

In industrial automation, Modbus TCP/RTU is one of the most widely adopted communication standards. To bridge the gap between M-Bus and Modbus, ICP DAS developed the GW-7838-M gateway, which enables seamless transmission of meter data from M-Bus to Modbus TCP/RTU. The GW-7838-M supports communication with up to 100 M-Bus devices. Once configured using the M-Bus utility, the gateway can autonomously collect meter data. A PLC or PC acting as a Modbus TCP/RTU client can then access this data via a TCP or RS-232 connection with ease.

Application

The M-Bus (Meter-Bus) is a communication bus specifically designed for reading data from measurement instruments such as energy meters, hot and cold water meters, gas meters, pressure sensors, actuators, and similar devices.

 

Specifications

Ethernet
Ports 1 x RJ-45, 10/100Base-T(X)
Protocol Modbus TCP
COM Ports
Ports 1 x RS-232, Non-isolated
Baud Rate 300 - 115200 bps
Parity None, Even, Odd, Mark, Space
Data Bit 5, 6, 7, 8
Stop Bit 1, 2
M-Bus
Ports 1
Baud Rate 300 - 2400 bps and user-defined baud rate
Data Bit 5, 6, 7, 8
Stop Bit 1, 2
Parity None, Even, Odd, Space, Mark
Isolation 3750 Vrms for photo-couple
Current Protection short-circuit protection
Power
Consumption 1.8 W @ 24 VDC (with 1 slave device), 11.8 W @ 24 VDC (with 100 slave devices)
Mechanical
Dimensions (mm) 102 x 123 x 40 (W x H x D)
Installation Wall mounting
Environment
Operating Temperature -25 - +75 Deg C
Storage Temperature -30 - +80 Deg C
Humidity 10 - 90% RH, Non-condensing

Add a review

Your email address will not be published. Required fields are marked *

Overall ratings
Select Rating *
You must be signed in to review! Click here to sign in.
Related Products
tDS-735i-UL-UTA
$389.00
tDS-735i-UL-UTA
$389.00
tDS-735-UL-UTA
$329.00
tDS-735-UL-UTA
$329.00
tDS-725i-UL-UTA
$379.00
tDS-725i-UL-UTA
$379.00
tDS-725-UL-UTA
$319.00
tDS-725-UL-UTA
$319.00
CA-RJ45-04
$59.00
PET-2261
$469.00
Connect with us

Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.

Join Our Newsletter

Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.

About Us

ICP DAS USA is a leading manufacturer of industrial data acquisition, data communication, programmable controllers, wireless and software solutions.