Smart greenhouses rely on accurate environmental monitoring to maintain suitable growing conditions for plants. The DLW-1023 Mini Weather Station measures temperature, humidity, wind speed, wind direction, atmospheric pressure, and illuminance. It also monitors particulate matter (PM1, PM2.5, and PM10), carbon monoxide (CO), and carbon dioxide (CO2) to provide additional information about air quality.
The collected data can be integrated into an IoT monitoring system to help operators evaluate greenhouse conditions and make informed decisions about ventilation, environmental management, and crop growth.
When combined with devices such as the PM-3133 Smart Power Meter and WISE-5231M-4GE Edge Controller, environmental and energy consumption data can be transmitted to a central monitoring system for analysis and management.
Weather and environmental monitoring are important for water management facilities, pumping stations, and other remote infrastructure.
The DLW-1023 can collect weather information such as wind speed, wind direction, temperature, humidity, and atmospheric pressure, along with particulate matter and CO/CO2 concentrations.
When integrated with the WISE-5231M-4GE Edge Controller and compatible sensors, environmental data can be transmitted alongside water quality, flow rate, water level, and valve monitoring information to a central control system.
This integration allows operators to remotely monitor environmental conditions, analyze trends, and make informed decisions about facility operations and maintenance.
Marine transportation and commercial ports require reliable environmental monitoring to support operational planning and air quality management.
The DLW-1023 measures wind speed, wind direction, temperature, humidity, atmospheric pressure, and illuminance. It also monitors particulate matter (PM1, PM2.5, and PM10), carbon monoxide (CO), and carbon dioxide (CO2).
These measurements can help port operators observe weather conditions and airborne pollutant concentrations associated with surrounding transportation and industrial activities.
By integrating the collected information into a centralized monitoring system, operators can analyze environmental trends and support air quality management initiatives at commercial ports and marine facilities.
The DLW-1023 collects environmental information, including temperature, humidity, wind speed, wind direction, atmospheric pressure, illuminance, particulate matter, CO, and CO2 concentrations.
These measurements can help agricultural operators evaluate weather conditions and air quality factors that may affect crop growth, greenhouse environments, and general farming operations.
CO2 monitoring is particularly useful in greenhouse applications where maintaining suitable carbon dioxide concentrations can support plant growth.
When combined with the WISE-5231M-4GE Edge Controller and compatible M-7000 data acquisition modules, the collected information can be integrated with additional environmental sensors across remote agricultural locations.
This combination supports centralized data collection, monitoring, and management to help farmers make informed decisions about agricultural operations.
Industrial facilities benefit from monitoring environmental conditions and airborne pollutant concentrations to support operational awareness and air quality management.
The DLW-1023 measures temperature, humidity, atmospheric pressure, illuminance, wind speed, and wind direction. It also monitors particulate matter (PM1, PM2.5, and PM10), carbon monoxide (CO), and carbon dioxide (CO2).
The device can be installed in suitable outdoor industrial environments to help monitor surrounding air quality and weather conditions near factories, warehouses, transportation facilities, and other industrial locations.
When integrated with the WISE-5231M-4GE Edge Controller, environmental data can be collected and transmitted to remote monitoring systems for analysis, alarm notifications, and operational decision-making.
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module, Communication (Programmable) |
| LED Indicators | |
|---|---|
| Status | PWR: Green for normal Operation Link: Green for the Ethernet-linked Alarm: Red for an alarm condition |
| System | |
|---|---|
| Alarm | Weather Monitoring (Wind Speed, Wind Direction, Pressure, Illuminance, Sea Level, RH/T), Particulates, Gas Monitoring (PM2.5, CO, CO2) |
| Real Time Clock | Yes |
| Data Logger | Yes |
| Relay Output | PhotoMOS Relay, Form Ax4, SPST 100VDC @ 1A |
| Temperature Measurement | |
|---|---|
| Range | -40 - +80 deg cel |
| Resolution | 0.1 deg Cel |
| Accuracy | 0.5 deg Cel |
| Humidity Measurement | |
|---|---|
| Range | 0 - 100% |
| Resolution | 0.1% |
| Accuracy | 5% |
| Life Time | 10 years |
| CO Measurement | |
|---|---|
| Range | 0 - 1000 ppm (Electrochemical) |
| Resolution | 1 ppm |
| Accuracy | 5% |
| Response Time | 30 seconds |
| Warm-up Time | 60 seconds |
| Life Time | 5 years |
| CO2 Measurement | |
|---|---|
| Range | 0 - 9999 ppm (NDIR) |
| Resolution | 1 ppm |
| Accuracy | +-3% |
| Response Time | 120 seconds |
| Warm-up Time | 300 seconds |
| Life Time | 15 years |
| Illuminance Measurement | |
|---|---|
| Range | 0 - 200,000 Lux |
| Resolution | 1 Lux |
| Accuracy | +- 5% |
| PM1/PM2.5/PM10 Measurement | |
|---|---|
| Range | 0 - 1000 ug/m3 |
| Resolution | 1 ug/m3 |
| Accuracy | +-10% |
| Response Time | 1 seconds |
| Warm-up Time | 20 seconds |
| Life Time | 5 years |
| Sea Level | |
|---|---|
| Range | -50 - 9000 m |
| Resolution | 0.1 m |
| Atmospheric Pressure | |
|---|---|
| Range | 300 - 1200 hPa |
| Accuracy | 1 hPa |
| Resolution | 0.1 hPa |
| Wind Speed | |
|---|---|
| Rnge | 0 - 40 m/s |
| Accuracy | 5% |
| Resolution | 0.01 m/s |
| Wind Direction | |
|---|---|
| Range | 0 - 359deg cel |
| Accuracy | <3 deg celsius |
| Resolution | 1deg celsius |
| Ethernet | |
|---|---|
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 |
| Access Control | Password and IP Filter |
| Protocol | Modbus TCP and MQTT |
| COM Ports | |
|---|---|
| Ports | 1 x RS-485 |
| Baud Rate | 1200 0 115200 bps |
| Protocol | Modbus RTU |
| Power | |
|---|---|
| Consumption | PoE: 3.33 W Max Non-PoE: 3.01 W Max |
| Powered from PoE | IEEE 802.3af, Class 1 (48 V) |
| Powered from Terminal Block | +12 to +48 VDC |
| Mechanical | |
|---|---|
| Dimensions (mm) | 288 x 122 x 389 (W x L x H) |
| Installation | U-bolt or Wall Mounting |
| Ingress Protection Rating | IP54 |
| Weight | 2.45 KG |
| Environment | |
|---|---|
| Operating Temperature | -20 to +50 deg cel |
| Storage Temperature | -30 to +75 deg cel |
| Humidity | 10% to 90% RH, Non-condensing |
Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.
Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.
Add a review
Your email address will not be published. Required fields are marked *