The ZT-2015 offers 6 wireless input channels, each of which can be connected to different kinds of RTD sensors. It features automatic compensation for 3-wire RTD, with long-distance measurement capabilities so that it can measure accurately regardless of the length of the wires. Also, the ZT-2015 is fully RoHS-compliant and has qualification for 4 kV ESD protection as well as 3000 VDC intra-module isolation. Users can easily configure the module's address, protocol, checksum, ZB-PID, ZB-channel, and type code settings using a combination of rotary and DIP switches.
| Communication Interface | |
| Wireless Standards | ZigBee 2007 Pro |
| Transmission Power | 11 dBm (FCC Certifi cated) ( Max 19 dBm) |
| 2.4 GHz Antenna | 5 dBi Omni directional |
| Transmission Range (LoS) | 700 m (Typical) |
| Certification | CE/FCC, FCC ID |
| Max. Slaves in a ZigBee Network | 255 |
| ZB-100R/ZB-100T Support | - |
| Protocols | Supports DCON and Modbus RTU Protocols |
| Hot Swap | Rotary and DIP switch |
| LED Indicators | |
| Power | 1 LED, red |
| ZigBee Communication | 1 LED, green |
| Isolation | |
| Intra-module Isolated, Field-to-Logic | 3000VDC |
| Power | |
| Power Consumption | 1.5 W Max. |
| EMS Protection | |
| ESD (IEC 61000-4-2) | ±4 kV Contact for Power Line, Communication Line and each Channel, ±8 kV Air for Random Point |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| Surge (IEC 641000-4-5) | ±3 kV for Power Line |
| Mechanical | |
| Flammability | Fire Retardant Materials (UL94-V0 Level) |
| Dimensions (W x L x H) | 33 mm x 87 mm x 107 mm |
| Installation | DIN-Rail |
| Environment | |
| Operating Temperature | -25°C ~ +75°C (-13°F ~ +167°F) |
| Storage Temperature | -30°C ~ +80°C (-22°F ~ +176°F) |
| Relative Humidity | 10 ~ 90% RH, Non-condensing |
| Analog Input | ||
| Input Channels | 6 | |
| Input Types | 2/3-wire RTD | |
| RTD Types | Pt100, Pt1000, Ni120, Cu100, Cu1000 | |
| Resolution | 16-bit | |
| Sampling Rate | 12 Samples/Sec. (Total) | |
| Accuracy | +/-0.05% | |
| Zero Drift | +/-0.5 μV/°C | |
| Span Drift | +/-20 μV/°C | |
| Common Mode Rejection | 150 dB | |
| Normal Mode Rejection | 100 dB | |
| Open Wire Detection | Yes | |
| Overvoltage Protection | 120 VDC/110VAC | |
| Individual Channel Configuration | Yes | |
| 3-wire RTD Lead Resistance Elimination | Yes | |