| Share On: | |
|---|---|
| Categories: | VPD Expansion Boards |
| Review: | Write your review |
| Resources: |
The XV306 is a multifunction expansion board that includes 4 Analog Input channels, 4 Digital Input channels and 4 Form A Relay Output channels. It provides a programmable input range on all Analog Input channels (+/-1 V, +/-2.5 V, +/-5 V, +/-10 V, +/-20 mA, 0 ~ +20 mA or +4 ~ +20 mA), and voltage and current outputs are jumper selectable. The Digital Input channels can be used as 32-bit counters. The XV306 also provides options for configuring power-on values for the Digital Output. 4 kV ESD protection and 2000 VDC intra-module isolation are also provided to enhance noise immunity capabilities in industrial environments.
Communication |
Interface |
RS-232/TTL |
Format |
N, 8, 1 |
Baud Rate |
115200 bps |
Protocol |
Modbus/RTU |
Isolation |
|
Intra-module Isolation, Field-to-Logic |
2000 VDC |
EMS Protection |
|
ESD (IEC 61000-4-2) |
±4 kV Contact For Each Terminal, ±8 kV Air For Random Terminal |
Power |
|
Powered from Terminal Block |
5 VBC |
Consumption |
1.6 W Max. |
Mechanical |
|
Dimensions (W x L x H) |
82 mm x 59 mm x 13 mm |
Environment |
|
Operating Temperature |
-25 ~ +75°C |
Storage Temperature |
-30 ~ +80°C |
Humidity |
10 ~ 90% RH, Non-condensing |
Analog Input |
|
Channels |
4 |
Type |
±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA (Jumper Selectable) |
Resolution |
16-bit |
Sampling Rate |
Normal Mode, 10Hz |
Sampling Rate |
Fast Mode, 200Hz |
Sampling Rate |
Normal Mode, ±0.1 % |
Sampling Rate |
Fast Mode, ±0.5 % |
Overvoltage Protection |
47 VDC |
Digital Input/Counter |
|
Input Channels |
4 |
Type |
Dry Contact - , Wet Contact - Sink/Source |
ON Voltage Level |
Yes |
Power-on Value |
Yes, Programmable |
Relay Output |
|
Channels |
4 |
Type |
Power Relay |
Form A Relay, Contact Rating, |
6 A @ 35 VDC
6 A @ 240 VAC |
Form A Relay, Contact Rating |
10 ~ 40 VDC |
Form A Relay, Min. Contact Load |
100 mA @ ≧12 V |
Form A Relay,Contact Material |
Silver Cadmium Alloy |
Form A Relay,Operate Time |
5 ms (typical) |
Form A Relay, Release Time |
1 ms (typical) |
Form A Relay, Mechanical Endurance, |
30 x 106 ops. |
Form A Relay, Electrical Endurance |
1 x 105 ops. |
Power On Value |
Yes |
Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.
Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.
Add a review