FREE $30.00 Visa Gift Card with CODE: VISA for registered customer's FIRST-TIME purchase.

Cage/NCage Code 3FNF0

Orders ship within a week!

WISE-7115

$689.00
7-channel RTD Input with 3-wire RTD lead resistance elimination PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP. MiniOS7 Operating System.
Availability: IN STOCK | FASTEST DELIVERY : Saturday, Oct 10 | Enter ZIP below for shipping options
Get Shipping Options
QTY
-
+

WISE-7115 is a Web Inside Smart Engine (WISE) device developed by ICP DAS. Fit for use as a control units for remote logic control and monitoring, WISE-7115 provides an intuitive and user-friendly web interface that allows users to implement IF-THEN-ELSE control logic on controllers with limited to no programming by the user. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.

The WISE-7115 device adheres to the IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. With the ability to receive power from PoE enabled networks through Ethernet pairs (Category 5 Ethernet cable), this gives greater flexibility, higher efficiency, and simplified systems design which thus saves space, reducees cables usage, and eliminate the need for additional electrical outlets. For non-PoE environment, the WISE-7115 device can still be powered through other power sources such as AC adapters and batteries.

The WISE-7115 module supports Modbus/TCP protocol for seamless integration with SCADA software. It features a 16-bit, 3-wire 7-channel RTD input. Each channel (supported by 3-wire RTD lead resistance elimination) is individually configurable for various temperature ranges.

  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule engine for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • AI Type: 7 RTD (Pt100, Pt1000, Ni120, Cu100, Cu1000)
  • Individual Channel Configuration
  • 3-wire RTD Input with Lead Resistance Elimination
  • 2-way Isolation/ESD Protection

Specifications

Analog Input
Input Channels
7 (Differential)
Sensor Type
Pt100, Pt1000, Ni120, Cu100, Cu1000
Wire Connection
2/3 wire
Resolution
16-bit
Sampling Rate
12 Samples/Sec. (Total)
Accuracy +/-0.05%
Zero Drift +/-0.5 μV/°C
Span Drift +/-20 μV/°C
Common Mode Rejection 150 dB
Normal Mode Rejection 100 dB
Input Impedence > 1M Ω
Open Wire Detection Yes
Individual Channel Configuration Yes
3-wire RTD Lead Resistance Elimination
Yes
System
CPU
16-bit CPU
SRAM 512 KB
Flash Memory 512 KB
EEPROM 16 KB
Watchdog Yes
Communication
PoE Ethernet Port
10/100 Base-TX and automatic MDI/MDI-X
2 Way Isolation
I/O
2500 VDC
EMS Protection
ESD (IEC 61000-4-2)
±4 kV Contact for each terminal and ±8 kV Air for random point
EFT (IEC 6000-4-4)
±4 kV for Power Line
LED Indicators
PoE PoE On
L1 System Running
L2 Ethernet Link/Act
L3
Ethernet 10/100M Speed
Power Requirements
Reserve Polarity Protection
Yes
Powered from terminal block
Yes, 12 ~ 48 VDC
Powered from PoE Yes, IEEE 802.3af, Class 1
Consumption
2.6 W
Mechanical
Dimensions (W x H x D)
72 mm x 123 mm x 35 mm
Installation
DIN-Rail or Wall Mounting
Environmental
Operating Temperature
-25°C ~ +75°C (-13°F ~ +167°F)
Storage Temperature
-30°C ~ +80°C (-22°F ~ +176°F)
Ambient Relative Humidity
10 ~ 90% RH, non-condensing

Software Specification

Functions
Rule Configuration Website
Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers
Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers
Delay / Timing functions.
12 Emails
Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
8 P2P Remote Set up the connection information for the remote WISE modules.
Modbus/ TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
AI Channel
=, >, <, >=, <=(value)
Internal Register
Timer Timeout, Not Timeout
P2P DI, AI, DI counter, IR
Rule Status Enable, Disable
THEN / ELSE Actions
Internal Register
Change the value
Timer Start, Stop
Email Send
CGI Commands
Recipe Execute
P2P DO (On/Off), AO, IR
Rule Status Enable, Disable

Add a review

Your email address will not be published. Required fields are marked *

Overall ratings
Select Rating *
You must be signed in to review! Click here to sign in.
Related Products
WISE-7144
$449.00
WISE-7117
$589.00
NS-205PSE
$359.00
Connect with us

Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.

Join Our Newsletter

Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.

About Us

ICP DAS USA is a leading manufacturer of industrial data acquisition, data communication, programmable controllers, wireless and software solutions.