MDR-20-24

$139.00
24V / 1A 24W Industrial Power Supply with DIN Rail Mount. Voltage input range is 85 ~ 264VAC or 120 ~ 370VDC.
Availability: IN STOCK | FASTEST DELIVERY : Sunday, Oct 11 | Enter ZIP below for shipping options
Get Shipping Options
QTY
-
+
Share On:
Categories: Power Supplies
Review: Write your review
Resources:
  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • NEC class 2 / LPS compliant
  • Built in DC OK active signal
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • 3 years warranty

Specifications

Input
Voltage range 85 ~ 264 VAC
120 ~ 370 VDC
Frequency range 47 ~ 63Hz
Efficiency (Typ.) 84%
AC Current (Typ.) 0.55 A/115 VAC
0.35 A/230 VAC
Inrush Current (Typ.) COLD START 20 A/115 VAC
40 A/230 VAC
Leakage current <1 mA / 240 VAC
Output
DC Voltage 24 VDC
Rated Current 1 A
Current Range 0 ~ 1 A
Rated power 24 W
Ripple & noise (max.)  Note.2 150mVp-p
Voltage ADJ. range 21.6 ~ 26.4 V
Voltage Tolerance        Note.3 ±1.0%
Line Regulation ±1.0%
Load regulation ±1.0%
Setup, rise Time           Note.5 50 ms/230 VAC
0 ms/115 VAC at full load
Hold up time (Typ.) 85 ~ 264 VAC
120 ~ 370 VDC
Protection
Overload 105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
Function
DC OK Active Signal (max.) 18 ~ 27 V/20 mA
Environmental
Working temp. -20 ~ +70°C (Refer to output load derating curve)
Working humidity 20 ~ 90% RH non-condensing
Storage TEMP., humidity -40 ~ +85°C , 10 ~ 95% RH
TEMP. Coefficient ±0.03%/°C (0 ~ 50°C)
Vibration Component:10 ~ 500Hz, 2G 10min./1cycle, 
60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
Safety & EMC (Note 4)
Safety standards UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant
Withstand voltage I/P-O/P:3KVAC    I/P-FG:1.5KVAC    O/P-FG:0.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI Conduction & Radiation Compliance to EN55011,EN55022 (CISPR22), EN61204-3 Class
Hsrmonic current Compliance to EN61000-3-2,-3
EMS immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
Others
MTBF 236.9K hrs min.
MIL-HDBK-217F (25°C )
Dimension (WxHxD) 22.5mm x 90mm x 100mm
Packing 0.19Kg; 72pcs/14.7Kg/0.91CUFT
NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
  5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

 

Application of DC OK Active Signal

 
accessories
   

Derating Curve

Output Derating VS Input Voltage

accessories 2 accessories 3

Add a review

Your email address will not be published. Required fields are marked *

Overall ratings
Select Rating *
You must be signed in to review! Click here to sign in.
Related Products
MDR-60-48
$179.00
MDR-60-24
$169.00
DR-120-48
$219.00
Connect with us

Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.

Join Our Newsletter

Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.

About Us

ICP DAS USA is a leading manufacturer of industrial data acquisition, data communication, programmable controllers, wireless and software solutions.