| Share On: | |
|---|---|
| Categories: | CAN Communication Converters | CANBus Converters and Gateways |
| Review: | Write your review |
| Resources: |
Available end of June 2015
The I-2533CS-60 is a local CAN bridge used to establish a connection between two CAN bus system via single mode fiber optic transmission medium. In order to solve the problem between CAN and fiber transmission medium, the I-2533CS-60 device is specially designed for converting the electrical CAN bus signal to fiber optic cables. The I-2533CS-A/B supports Wavelength Division Multiplexing (WDM) technology so that only a single fiber cable is needed for transmitting bi-directional CAN data. As the I-2533CS-A and I-2533CS-B must be paired because of hardware limitations, this means that the cost of deploying fiber cable can be effectively reduced.
I-2533CS-60 model has three more important features. First, the transmission distance limitation of the CAN bus system will not affected due to the different CAN baud rate. It means that the total CAN bus working distance can be extended. Second, the bus error on one CAN network will not affect the operation of another CAN network. Finally, the two CAN network can communication with each other by using different CAN baud rate for highly flexibility.
| CAN Interface | |
| Connector | Screwed terminal block (CAN_GND, CAN_L, CAN_H) |
| Baud Rate (bps) | 10 k ~ 1 M |
| Transmission Distance (m) | Depend on baud rate |
| Terminator Resistor | Switch for 120Ω terminator resistor |
| Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
| Specification | ISO 11898-2, CAN 2.0A and CAN 2.0B |
| Fiber Interface | |
| Type | SC Duplex type ; Single mode ; 100 Base-FX |
| Wave Length (nm) | 1310 |
| Fiber Cable (μm) | 8.3/125, 8.7/125, 9/125 or 10/125 |
| Transmission Distance (km) | 60 (indicative only) |
| Min. TX Output (dBm) | 5 |
| Max. TX Output (dBm) | 0 |
| Max. RX Sensitivity (dBm) | -35 |
| Max. RX Overload (dBm) | -5 |
| Budget (dBm) | 30 |
| UART Interface | |
| COM1 | RS-232 (configuration only) |
| COM1 Connector | Screwed terminal block (RXD, TXD, GND) |
| LED | |
| Round LED | PWR, FB_Ack, FB_Err, CAN_Err, CAN_Tx and CAN_Rx LEDs |
| Power | |
| Power supply | Unregulated +10 ~ +30 VDC |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection |
| Power Consumption | 0.125 @ 24VDC |
| Mechanism | |
| Installation | DIN-Rail |
| Dimensions | 33.0 mm x 126 mm x 101 mm (W x L x H) |
| Environment | |
| Operating Temp. | -25°C ~ +75°C (-13°F ~ +167°F) |
| Storage Temp. | -30°C ~ +80°C (-22°F ~ +176°F) |
| Humidity | 10 ~ 90% RH, non-condensing |
Network Deployment:

| CAN Baud rate [bit/sec] | Ideal Fiber Length [km] |
| 1M | 30 |
| 800K | 30 |
| 500K | 30 |
| 250K | 30 |
| 125K | 30 |
| 50K | 30 |
| 20K | 30 |
| 10K | 30 |
CAN Bus Distance:

Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.
Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.
Add a review