The ET-M8194H is a new product from ICP DAS that can be used to implement remote control functionality via the Ethernet and includes an I-8094H module (a 4-axis stepping/pulse-type servo motor control module with an embedded CPU) and an Ethernet communication interface. The intelligent ET-M8194H can provide users with the ability to develop a wide range of remote motion control applications, and can be integrated in any system where the host platform is built on the Modbus TCP protocol (for example: PC, PAC or PLC). In addition, implementing a multi-station, multi-axis motion control solution can easily be achieved by cascading several ET-M8194H devices using Ethernet cables, either with or without Ethernet switches. ICP DAS also provides the EzMove Utility and an API Library that can be used to configure the ET-M8194H and to rapidly develop customized control applications.
|
![]() |
|
![]() |
| Interpolation Functions | Linear Interpolation (Interpolation Speed: 4 Mpps): 32-bit max. for any single command Circular Interpolation (Interpolation Speed: 4 Mpps): 32-bit max. for any single command Continuous Interpolation (Interpolation Speed: 2 Mpps): Yes |
| Drive Speed Curve | Maximum Drive Speed: 4 Mpps Constant Speed Driving Trapezoidal Acc/Dec Driving Asymmetrical Trapezoidal Driving S-curve Acc/Dec Driving Asymmetrical S-curve Driving |
| Position Control | Logic Position Counter/Bit Length for output pulse: 32-bit Real Position Counter/Bit Length for output pulse: 32-bit Position Compare Register Number/Axis: 2 Software Limit Position Counter Variable Ring |
| Auto-Home Search | Individual configuration (4-step) for each axis including irregular operation handling |
| Synchronous Action | 10 activation factors (provocatives or events) and 14 actions |
| External Signal for Driving | Fixed/Continuous Pulse Output Manual Pulse |
| Other Functions | Drive Speed/Output Pulse Number Change during Driving Triangle Form Prevention of Speed Curve |
| Servo Motor Signal | Servo Ready and Alarm Input Signals/Axis Servo Enable Output/Axis |
| Other Input Signals | IN0 (Near Home), IN1 (Home), IN2 (Z-phase), IN3/Axis Emergency Signal |
| Input Signal Integral Type Filter | Filter Time Constant: 2 ~ 16 ms, 8 stages |
| Environmental | Operating Temperature: -20 ~ +75°C Storage Temperature: -30 ~ +85°C Operating Humidity: 10 ~ 85% RH, non-condensing Storage Humidity: 5 ~ 90% RH, non-condensing |
| FRnet Interface | Max. 128 DI and 128 DO channels Hardware auto-scan I/O every 0.72 ms 2-wire Serial Bus to reduce wiring needs Max. communication distance: 100 M A wide range of FRnet I/O terminal boards and modules are available |