| Share On: | |
|---|---|
| Categories: | DeviceNet Data Acquisition |
| Review: | Write your review |
| Resources: |
DeviceNet is one kind of the network protocols based on the CAN bus and mainly used for the embedded network of the machine control, such as industrial machine control , aircraft engines monitoring, factory automation, medical equipments control, remote data acquisition, environmental monitoring, and packaging machines control, etc.
The CAN-2024D follows DeviceNet specification Volume I/II, Release 2.0. User can access the analog output status and set the configuration via DeviceNet EDS file. CAN-2024D has 4-channel 14-bit analog output and it can be used to various applications. By the DeviceNet masters of ICP DAS, you can quickly build a DeviceNet network to approach your requirements. For more information about the DeviceNet master interfaces and other DeviceNet products, please refer to the following web site.

DeviceNet Interface |
|
DeviceNet Specification |
Volume I, Release 2.0 & Volume II, Release 2.0, Errata5 |
DeviceNet subscribe |
Group 2 Only Server |
Connection supported |
1 connection for Explicit Messaging 1 connection for Polled I/O 1 connection for Bit-Strobe I/O |
Baud Rate Setting by Rotary Switch |
125 kbps, 250 kbps, 500 kbps |
Node ID Setting by Rotary Switch |
0 ~ 63 |
Heartbeat message |
Yes |
Shutdown message |
Yes |
Terminator Resistor |
Switch for 120 Ω terminator resistor |
Connector |
5-pin screwed terminal block (CAN_GND, CAN_L, CAN_SHLD, CAN_H, CAN_V+) |
EDS file |
Yes |
LED |
PWR/NET/MOD |
Analog Output |
|
Channels |
4 |
Output Type |
0~ 5 V, +/- 5 V, 0~ 10 V, +/- 10 V, 0 ~ 20 mA, 4 ~ 20 mA |
Resolution |
14-bit |
Accuracy |
+/- 0.1 % of FSR for voltage output ; +/- 0.2 % of FSR for current output |
Zero Drift |
Voltage: +/-30μV/°C Current: +/-0.2μV/°C |
Span Drift |
+/-20ppm/°C |
Voltage Output Capability |
10V@5mA |
Max Current Load Resistance |
External +24 V : 1050 Ohms |
Power-Up and Safe Value |
Yes |
4KV ESD Protection |
Yes, Contact for each terminal. |
Intra-module Isolation, Field to Logic |
3000 VDC |
LED |
|
DeviceNet Status |
3 LEDs for PWR/NET/MOD |
Terminal Resister |
1 LED as terminal resister indicators |
AO LED |
8 LEDs as analog output indicators |
Power |
|
Power Supply |
Unregulated +10 ~ +30 VDC |
Power Consumption |
1.5 W |
Mechanism |
|
Installation |
DIN-Rail |
Dimensions |
32.3 mm x 99 mm x 77.5 mm ( W x L x H ) |
Environment |
|
Operating Temp. |
-25 ~ 75 ℃ |
Storage Temp. |
-30 ~ 80 ℃ |
Humidity |
10 ~ 90% RH, non-condensing |
Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.