WISE-7153 is equipped with 16-channel dry contact digital inputs; each digital input channel supports counter input. WISE-7153 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency. With this design, it eliminates space, reduces the use of cables and eliminates the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7153 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.
Digital Input
Input Channels
16
Input Type
Dry Contact (Source)
On Voltage Level
Close to GND
Off Voltage Level
Open
Counters
Max. Count
65535 (16 bits)
Max. Input Frequency
50 Hz
Min. Pulse Width
10 ms
System
CPU
16-bit CPU
SRAM
512 KB
Flash Memory
512 KB
EEPROM
16 KB
Watchdog
yes
Communication
PoE Ethernet Port
10 / 100 Base-TX and Automatic MDI/MDI-X
2 Way Isolation
I/O
2500 VDC
EMS Protection
ESD (IEC 61000-4-2)
+/-4 kV Contact for each terminal and ±8 kV Air for random point
EFT (IEC 61000-4-4)
+/-2 kV for Power Line
LED Indicators
PoE
PoE On
L1
System Running
L2
Ethernet Link/Act
L3
Ethernet 10/100M Speed
Power Requirements
Reserve Polarity Protection
Yes
Powered from terminal block
Yes, 12 ~ 48 VDC
Powered from PoE
Yes, IEEE 802.3af, Class1
Consumption
3.0 W
Mechanical
Dimensions (W x H x D)
72 mm x 123 mm x 35 mm
Installation
DIN-Rail or Wall mounting
Environment
Operating Temperature
-25 °C ~ +75 °C
Storage Temperature
-30 °C ~ +80 °C
Humidity
10 ~ 90% RH, non-condensing
Functions
Rule Configuration Website
Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers
Hold temporary variables and read/write data via Modbus TCP address.
12 Timers
Delay / Timing functions.
12 Emails
Send Email messages to pre-set Email receivers.
12 CGI Commands
Send pre-set CGI commands.
12 Recipes
Set up THEN/ELSE action groups.
8 P2P remote modules
Set up the connection information for the remote WISE modules.
Modbus TCP Protocol
Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel
ON, OFF, ON to OFF, OFF to ON, Change
Internal Register
=, >, <, ≥, ≤ (value)
DI Counter
=, >, <, ≥, ≤ (value), Change
Timer
Timeout, Not Timeout
P2P
DI, AI, DI counter, DO counter, IR
Rule Status
Enable, Disable
THEN / ELSE Actions
Internal Register
Change the value
DI Counter
Reset
Timer
Start, Reset
Send
CGI Commands
Send
Recipe
Execute
P2P
DO(On/Off), AO, IR
Rule Status
Enable, Disable