| Share On: | |
|---|---|
| Categories: | I-87KW High Performance I/O Modules |
| Review: | Write your review |
| Resources: | The product additional data is empty. |
The I-87061PW is a 16-channel Power Relay Output module where each Relay Output channel is independent. The I-87061W is a 16-channel power relay output module with the output channels partitioned into four groups, where each group provides four channels that share a single COM point. Both the I-87061W and I-87061PW modules include 16 LED indicators that can be used to monitor the status of the relay output, and options for configuring both power-on and safe relay output values are also available. 4 kV ESD protection and 3750 VDC intra-module isolation are provided as standard to enhance the noise protection capabilities in harsh industrial environments.
Applications:
|
Relay Output
|
|||
|
Channels
|
16 (Form A) | ||
|
Type
|
Power Relay | ||
|
Wiring
|
Four groups, each group providing four channels that share a single COM point.
|
Differential | |
|
Form Relay
|
Contact Rating |
10 A @ 250 VAC/per Module COM point
10 A @ 24 VDC/per Module COM point Max. Single Relay Load Current 5 A at 25°C |
3 A @ 250 VAC/per Channel 3 A @ 24 VDC/per Channel |
| Min. Contact Load | 10 mA @ 5 V | ||
| Contact Material | Silver Tin Alloy | ||
| Operating Time | 10 ms | ||
| Release Teime | 5 ms | ||
| Mechanical Endurance | 2 × 10^7 ops. | ||
| Electrical Endurance | 1 × 10^5 ops. | ||
|
Power-on Value
|
Yes
|
||
|
Safe Value
|
Yes
|
||
|
Communication
|
|||
| Interface | RS-485 | ||
| Format | N, 8, 1 | ||
| Baud Rate | 1200 ~ 115200 bps | ||
| Protocol | DCON | ||
| Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | ||
| LED Indicators/Display | |||
| System LED Indicator | 1 as Power/Communication Indicator | ||
| Yes, 16 as Power Relay Output Indicators | |||
|
I/O LED Indicator
|
14 ~ 17V
|
||
| Protection type : Shut down o/p voltage with auto-recovery | |||
|
7-Segment LED Display
|
-
|
||
| Isolation | |||
| Intra-module Isolation, Field-to-Logic | 3750 VDC | ||
|
EMS Protection
|
|||
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | ||
| ±8 kV Air for Random Point | |||
| Power | |||
| Power Consumption | 1.5 W Max. | 1.9 W Max. | |
| Mechanical | |||
| Dimensions | 102 mm x 30 mm x 115 mm | 100 mm x 30 mm x 114 mm | |
|
Environment
|
|||
| Operating Temperature | -25°C ~ +75°C (-13°F ~ +167°F) | ||
| Storage Temperature | -40°C ~ +85°C (-40°F ~ 185°F) | ||
|
Humidity
|
10 ~ 95% RH, Non-condensing
|
||
Our mission is to provide the absolute best customer experience in industrial automation and electronics, without exception.
Subscribe to our mailing list today and join thousands of others who want to stay up-to-date with the latest news in data acquisition and industrial data communication.
Add a review
Your email address will not be published. Required fields are marked *