ICP DAS USA’s DL-302-IP65 Data Logger device records CO, CO2, Temperature, Humidity and Dew Point information, including date and time stamps, and stores up to 450,000 downloadable records. The DL-302-IP65 allows the user to access real-time data by using the free Windows software, the iOS App or the Android App, as long as they are connected to the same local network as the Data Logger. Support is provided for popular industrial protocols such as DCON, Modbus RTU, as well as the emerging machine-to-machine (M2M)/IoT(Internet of Things) connectivity protocol - MQTT. The DL-300 Data Logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system.
Mushroom growth yield requires long time to monitor the environment of CO2 concentration, temperature and humidity values, and its growth environment is high humidity condition. The general equipment cannot work in such environment, but the DL-302-IP65 can be used to record CO2, temperature, humidity and dew point information with date and time stamps in the operating temperature from -20°C to +50°C, and are able to store up to 450,000 downloadable records . The WISE-5231-3GWA features timer and schedule functions. It allows user to schedule specific date or time for control logic execution, or perform specific tasks such as time delay. With calendar user interface provided, schedule setting can be more efficient and fl exible. This does not require programming, only some simple settings will be able to achieve the farm production control and quality control, production resume ... and so on.
CO2 Measurement
Range
0 to 9999 ppm (NDIR)
Resolution
1 ppm
Accuracy
±70 ppm ±5% of measured value
Response Time
120 sec
Warm-up Time
60 sec
Temperature Measurement
Range
-10 to +50°C
Resolution
0.1°C
Accuracy
±0.6°C
Relative Humidity Measurement
Range
0 to 100% RH, Non-condensing
Resolution
0.1% RH, Non-condensing
Accuracy
±5% RH, Non-condensing
Dew Point
Range
Calculated using temperature and relative humidity
Resolution
0.1°C
System
CO2 Alarm
Yes
Real-time Clock
Yes
Data Logger
Yes, 450,000 Records
Relay Output
Form A×1, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Interface
RS-485/Ethernet/PoE
Main Machine Interface
LCD
2.8 TFT (Resolution 240 x 320 x 16), Defective Pixels <= 3
Backlight Life
20,000 hours
Brightness
160 cd/m2
Touch Panel
Yes
Electrical
Powered from Terminal Block
+12 to +48 VDC
Powered from PoE
IEEE 802.3af, Class 1 (48 V)
Power Consumption (PoE)
2.65 W (Max.)
Power Consumption (Non-PoE)
2.14 W (Max.)
Mechanical
Dimensions (L x W x H)
170 mm x 211 mm x 60 mm
Installation
DIN-Rail or Wall Mounting
Environment
Operating Temperature
0 to +50°C
Storage Temperature
-30 to +75°C
Humidity
10 to 90% RH, Non-condensing
Protection Class
IP65